PurePoint Analytical
Verified by PurePoint · Passed all tests
8Point Tested
Alamo Peptides logo

Certificate of Analysis

Alamo Peptides

Retatrutide

99.57%

Purity

Code PP-QMY4UH · Issued 8/31/2026

Download PDF
High PurityIdentity ConfirmedNet Content VerifiedSterile · No GrowthFentanyl FreeEndotoxin Within LimitsHeavy Metals Within Limits

Sample Information

Product
Retatrutide
Marketing Name
AP-RT
Lot / Batch
AP-RT30-0926
Labeled Size
30 mg
Mol. Formula
C221H342N46O68
CAS Number
2381089-83-2
Cap Color
Gold
Crimp Color
Silver

Identity Confirmation (LC-MS)

Pass

LC-MS (ESI+)

Reference Standard
Confirmed match to labeled compound
Identity
Confirmed

Heavy Metal Analysis

Pass

ICP-OES, USP <232>/<233>

Reference Standard
Within USP <232>/<233> elemental impurity limits

Purity Analysis (HPLC/UV)

Pass

HPLC with UV-Vis Detection

Reference Standard
>98%
Purity
99.57%

Endotoxin Analysis

Pass

Kinetic Chromogenic LAL, USP <85>

Reference Standard
Not detected above 5 EU/mL (USP <85>)

Fentanyl Presence Analysis

Pass

Targeted LC-MS/MS Screening

Reference Standard
Not detected

Net Content / Quantity Check

Pass

Gravimetric + HPLC Quantitation

Reference Standard
30mg ± 10%
Net Content
30.89 mg

Rapid Sterility Screen

Pass

Membrane Filtration + Chromogenic Detection

Reference Standard
No microbial growth observed

Conformity Vial (Batch Verification)

Pass

HPLC Comparison to Reference Vial

Purity
99.57%
Net Content
30.89 mg
VialPurity (%)Net Content (mg)
Vial 1 (submitted)99.4530.7
Vial 2 (conformity)99.6530.85
Vial 3 (conformity)99.6131.12
Purity, batch mean
99.57%
SD 0.086 · n=3
Net content, batch mean
30.89 mg
SD 0.174 · n=3

Sample Photo

Retatrutide 30mg vial

Methods & Notes

  • The sample was confirmed to be Retatrutide by LC-MS (ESI+). Identification by comparison of observed mass against the expected molecular weight.
  • Elemental impurities quantified by ICP-OES per general principles of USP <232>/<233>. Screened elements include lead, mercury, arsenic, and cadmium.
  • Peptide purity determined by reversed-phase HPLC with UV detection at 214 nm. Value represents the percentage of the target compound relative to all detected compound-related peaks.
  • Additional vials from the same lot and concentration were compared against the primary tested vial by HPLC to confirm consistency across the production run. See Batch Conformity Results below for per-vial figures.
  • Bacterial endotoxin quantified by kinetic chromogenic LAL per general principles of USP <85>. Result reported in EU/mL against the defined acceptance limit for the sample type.
  • Targeted screening for fentanyl and common fentanyl analogs performed by LC-MS/MS. Result reported as detected or not detected against an established cutoff threshold.
  • Net content determined gravimetrically and cross-referenced against HPLC peak area quantitation relative to a characterized reference standard.
  • Preliminary microbial contamination screening performed by membrane filtration with chromogenic detection; results are read after 24 to 48 hours of incubation. This screen is a fast preliminary indicator and is not a substitute for full compendial sterility testing.

Sample identifications, product names, and lot numbers are provided by the submitting party and are not independently verified. Results reflect only the specific sample submitted and are not an evaluation of the manufacturer's processes or overall production. PurePoint Analytical is an independent analytical testing laboratory.

Reviewed & approved

Micah Lunsford signature

Micah Lunsford

Senior Analytical Chemist, PurePoint Analytical

Issued

8/31/2026

Verification QR code

Scan to verify on any device

Point a phone camera at the code, or share purepointanalytical.com/coa/PP-QMY4UH

Independently tested & verified by PurePoint Analytical.

This page is the authoritative public record for code PP-QMY4UH. Verify any certificate at purepointanalytical.com/coa.

Results are for research use only and are not for human consumption, clinical, diagnostic, or therapeutic use.